Energy Performance Certificate

27, Beech Street, Padiham, BB12 7EE

EPC Report

Energy rating

Current: 10 G | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 10 G Current: 10 G 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 22 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 93 Potential: 93
Field Value
LMK KEY 8196-6291-5629-9997-8973
ADDRESS1 27, Beech Street
ADDRESS2 Padiham
ADDRESS3
POSTCODE BB12 7EE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 10
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-11-11
LOCAL AUTHORITY E07000117
CONSTITUENCY E14001142
COUNTY
LODGEMENT DATE 2013-11-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 681
ENERGY CONSUMPTION POTENTIAL 41
CO2 EMISSIONS CURRENT 8.0
CO2 EMISS CURR PER FLOOR AREA 121
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 61
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 1605
HEATING COST POTENTIAL 321
HOT WATER COST CURRENT 449
HOT WATER COST POTENTIAL 59
TOTAL FLOOR AREA 67
ENERGY TARIFF Unknown
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 27, Beech Street, Padiham
LOCAL AUTHORITY LABEL Burnley
CONSTITUENCY LABEL Burnley
POSTTOWN BURNLEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-11-11 14:07:51
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100010328664
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew