Energy Performance Certificate

12, Harding Close, SN7 7SJ

EPC Report

Energy rating

Current: 74 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 75 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 90 Potential: 90
Field Value
LMK KEY 8193-2160-4529-2107-6953
ADDRESS1 12, Harding Close
ADDRESS2
ADDRESS3
POSTCODE SN7 7SJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-11-06
LOCAL AUTHORITY E07000180
CONSTITUENCY E14001591
COUNTY
LODGEMENT DATE 2015-11-06
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 178
ENERGY CONSUMPTION POTENTIAL 56
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 53
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 307
HEATING COST POTENTIAL 313
HOT WATER COST CURRENT 133
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 60
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12, Harding Close
LOCAL AUTHORITY LABEL Vale of White Horse
CONSTITUENCY LABEL Witney
POSTTOWN FARINGDON
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2015-11-06 12:28:36
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100120916655
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew