Energy Performance Certificate

21, Brampton Road, ST5 0PA

EPC Report

Energy rating

Current: 16 G | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 G Current: 16 G 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 5 | Potential: 47
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 5 Current: 5 47 Potential: 47
Field Value
LMK KEY 8191-1103-7129-4227-2243
ADDRESS1 21, Brampton Road
ADDRESS2
ADDRESS3
POSTCODE ST5 0PA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 16
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-12-20
LOCAL AUTHORITY E07000195
CONSTITUENCY E14001380
COUNTY
LODGEMENT DATE 2014-12-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 5
ENVIRONMENT IMPACT POTENTIAL 47
ENERGY CONSUMPTION CURRENT 944
ENERGY CONSUMPTION POTENTIAL 337
CO2 EMISSIONS CURRENT 18
CO2 EMISS CURR PER FLOOR AREA 160
CO2 EMISSIONS POTENTIAL 6.5
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 2502
HEATING COST POTENTIAL 939
HOT WATER COST CURRENT 342
HOT WATER COST POTENTIAL 96
TOTAL FLOOR AREA 113
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 35
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 21, Brampton Road
LOCAL AUTHORITY LABEL Newcastle-under-Lyme
CONSTITUENCY LABEL Newcastle-under-Lyme
POSTTOWN NEWCASTLE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-12-20 11:36:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100031719291
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew