Energy Performance Certificate

173, Williams Way, HA0 2FT

EPC Report

Energy rating

Current: 85 B | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 91 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 91 Potential: 91
Field Value
LMK KEY 8188-7639-5000-2575-7906
ADDRESS1 173, Williams Way
ADDRESS2
ADDRESS3
POSTCODE HA0 2FT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 85
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-01-05
LOCAL AUTHORITY E09000005
CONSTITUENCY E14001123
COUNTY
LODGEMENT DATE 2018-01-05
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 91
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 61
ENERGY CONSUMPTION POTENTIAL 61
CO2 EMISSIONS CURRENT 0.7
CO2 EMISS CURR PER FLOOR AREA 11
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 138
HEATING COST POTENTIAL 138
HOT WATER COST CURRENT 87
HOT WATER COST POTENTIAL 87
TOTAL FLOOR AREA 61
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.19 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.65
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 173, Williams Way
LOCAL AUTHORITY LABEL Brent
CONSTITUENCY LABEL Brent West
POSTTOWN WEMBLEY
CONSTRUCTION AGE BAND 2018
LODGEMENT DATETIME 2018-01-05 11:58:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 202208239
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display
Nation ew