Energy Performance Certificate

8, The Oaks, Mary Tavy, PL19 9QR

EPC Report

Energy rating

Current: 57 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 51 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 68 Potential: 68
Field Value
LMK KEY 8168-7925-5210-3750-6992
ADDRESS1 8, The Oaks
ADDRESS2 Mary Tavy
ADDRESS3
POSTCODE PL19 9QR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-05-10
LOCAL AUTHORITY E07000047
CONSTITUENCY E14001552
COUNTY
LODGEMENT DATE 2018-05-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 209
ENERGY CONSUMPTION POTENTIAL 119
CO2 EMISSIONS CURRENT 6.3
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 160
LIGHTING COST POTENTIAL 93
HEATING COST CURRENT 693
HEATING COST POTENTIAL 548
HOT WATER COST CURRENT 162
HOT WATER COST POTENTIAL 131
TOTAL FLOOR AREA 137
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much Less Than Typical
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 28
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil, Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 28% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, The Oaks, Mary Tavy
LOCAL AUTHORITY LABEL West Devon
CONSTITUENCY LABEL Torridge and Tavistock
POSTTOWN TAVISTOCK
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2018-05-11 14:49:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100040396904
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000009
Address display
Nation ew