Energy Performance Certificate

8, Rainer Close, Stratton St. Margaret, SN3 4YA

EPC Report

Energy rating

Current: 71 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 72 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 Current: 72 90 Potential: 90
Field Value
LMK KEY 8152-7721-0600-3133-5992
ADDRESS1 8, Rainer Close
ADDRESS2 Stratton St. Margaret
ADDRESS3
POSTCODE SN3 4YA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-09-17
LOCAL AUTHORITY E06000030
CONSTITUENCY E14001536
COUNTY
LODGEMENT DATE 2012-09-18
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 72
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 164
ENERGY CONSUMPTION POTENTIAL 44
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 383
HEATING COST POTENTIAL 317
HOT WATER COST CURRENT 126
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 78
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, Rainer Close, Stratton St. Margaret
LOCAL AUTHORITY LABEL Swindon
CONSTITUENCY LABEL Swindon North
POSTTOWN SWINDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2012-09-18 08:14:08
TENURE
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100121151602
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000009
Address display
Nation ew