Energy Performance Certificate

24, Cocketts Drive, PE13 2JS

EPC Report

Energy rating

Current: 64 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 62 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 88 Potential: 88
Field Value
LMK KEY 8147-6024-4620-1983-3992
ADDRESS1 24, Cocketts Drive
ADDRESS2
ADDRESS3
POSTCODE PE13 2JS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-04-17
LOCAL AUTHORITY E07000010
CONSTITUENCY E14001390
COUNTY
LODGEMENT DATE 2013-04-19
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 224
ENERGY CONSUMPTION POTENTIAL 65
CO2 EMISSIONS CURRENT 3.4
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 583
HEATING COST POTENTIAL 380
HOT WATER COST CURRENT 103
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 79
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 24, Cocketts Drive
LOCAL AUTHORITY LABEL Fenland
CONSTITUENCY LABEL North East Cambridgeshire
POSTTOWN WISBECH
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-04-19 12:44:53
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100090079118
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000006
Address display
Nation ew