Energy Performance Certificate

46, Farringdon, North Petherton, TA6 6PF

EPC Report

Energy rating

Current: 54 E | Potential: 104 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 104 A Potential: 104 A

Environmental impact (CO₂)

Current: 47 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 95 Potential: 95
Field Value
LMK KEY 8145-7624-1940-0898-5906
ADDRESS1 46, Farringdon
ADDRESS2 North Petherton
ADDRESS3
POSTCODE TA6 6PF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 104
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-04-08
LOCAL AUTHORITY E06000066
CONSTITUENCY E14001126
COUNTY
LODGEMENT DATE 2015-04-08
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 228
ENERGY CONSUMPTION POTENTIAL -72
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 0.0
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 592
HEATING COST POTENTIAL 342
HOT WATER COST CURRENT 240
HOT WATER COST POTENTIAL 191
TOTAL FLOOR AREA 78
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cob, as built
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.18
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 46, Farringdon, North Petherton
LOCAL AUTHORITY LABEL Somerset
CONSTITUENCY LABEL Bridgwater
POSTTOWN BRIDGWATER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-04-08 18:19:30
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 200000440060
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew