Energy Performance Certificate

18 Victoria Court, Station Road, BA7 7NL

EPC Report

Energy rating

Current: 69 C | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 52 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 77 Potential: 77
Field Value
LMK KEY 8138-7720-2289-5703-3992
ADDRESS1 18 Victoria Court
ADDRESS2 Station Road
ADDRESS3
POSTCODE BA7 7NL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-10-17
LOCAL AUTHORITY E06000066
CONSTITUENCY E14001247
COUNTY
LODGEMENT DATE 2018-10-18
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 336
ENERGY CONSUMPTION POTENTIAL 139
CO2 EMISSIONS CURRENT 3.4
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 58
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 417
HEATING COST POTENTIAL 309
HOT WATER COST CURRENT 182
HOT WATER COST POTENTIAL 89
TOTAL FLOOR AREA 61
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 67
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 18 Victoria Court, Station Road
LOCAL AUTHORITY LABEL Somerset
CONSTITUENCY LABEL Glastonbury and Somerton
POSTTOWN CASTLE CARY
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2018-10-18 18:59:28
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 30007817
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000009
Address display
Nation ew