Energy Performance Certificate

24, St. Bernard Close, Broughton, DN20 0HS

EPC Report

Energy rating

Current: 53 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 49 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 81 Potential: 81
Field Value
LMK KEY 8136-7828-4310-1617-2922
ADDRESS1 24, St. Bernard Close
ADDRESS2 Broughton
ADDRESS3
POSTCODE DN20 0HS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-08-23
LOCAL AUTHORITY E06000013
CONSTITUENCY E14001128
COUNTY
LODGEMENT DATE 2016-08-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 342
ENERGY CONSUMPTION POTENTIAL 119
CO2 EMISSIONS CURRENT 4.8
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 965
HEATING COST POTENTIAL 556
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 81
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 24, St. Bernard Close, Broughton
LOCAL AUTHORITY LABEL North Lincolnshire
CONSTITUENCY LABEL Brigg and Immingham
POSTTOWN BRIGG
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2016-08-24 11:04:51
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 200000875660
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew