Energy Performance Certificate

29, Hillman Avenue, Jaywick, CO15 2JL

EPC Report

Energy rating

Current: 58 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 41 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 72 Potential: 72
Field Value
LMK KEY 8131-6529-5749-9834-2996
ADDRESS1 29, Hillman Avenue
ADDRESS2 Jaywick
ADDRESS3
POSTCODE CO15 2JL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2019-11-14
LOCAL AUTHORITY E07000076
CONSTITUENCY E14001174
COUNTY
LODGEMENT DATE 2019-11-22
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 540
ENERGY CONSUMPTION POTENTIAL 214
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 91
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 542
HEATING COST POTENTIAL 383
HOT WATER COST CURRENT 233
HOT WATER COST POTENTIAL 126
TOTAL FLOOR AREA 43
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 29, Hillman Avenue, Jaywick
LOCAL AUTHORITY LABEL Tendring
CONSTITUENCY LABEL Clacton
POSTTOWN CLACTON-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2019-11-22 08:26:45
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100090606396
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew