Energy Performance Certificate

Flat 59 Cheshunt House, Moorend Avenue, B37 5TB

EPC Report

Energy rating

Current: 64 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 61 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 75 Potential: 75
Field Value
LMK KEY 8121-6927-5350-8781-9922
ADDRESS1 Flat 59 Cheshunt House
ADDRESS2 Moorend Avenue
ADDRESS3
POSTCODE B37 5TB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2019-03-29
LOCAL AUTHORITY E08000029
CONSTITUENCY E14001358
COUNTY
LODGEMENT DATE 2019-04-01
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 281
ENERGY CONSUMPTION POTENTIAL 178
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 537
HEATING COST POTENTIAL 315
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 106
TOTAL FLOOR AREA 62
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 9.27
FLOOR HEIGHT 2.26
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 59 Cheshunt House, Moorend Avenue
LOCAL AUTHORITY LABEL Solihull
CONSTITUENCY LABEL Meriden and Solihull East
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2019-04-01 11:10:15
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100071340012
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000005
Address display
Nation ew