Energy Performance Certificate

1, Marsh Close, Cockerham, LA2 0EH

EPC Report

Energy rating

Current: 30 F | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 9 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 9 Current: 9 50 Potential: 50
Field Value
LMK KEY 8118-7828-5800-4933-4996
ADDRESS1 1, Marsh Close
ADDRESS2 Cockerham
ADDRESS3
POSTCODE LA2 0EH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-08-17
LOCAL AUTHORITY E07000121
CONSTITUENCY E14001318
COUNTY
LODGEMENT DATE 2018-08-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 9
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 864
ENERGY CONSUMPTION POTENTIAL 324
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 151
CO2 EMISSIONS POTENTIAL 5.5
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 90
HEATING COST CURRENT 1705
HEATING COST POTENTIAL 861
HOT WATER COST CURRENT 572
HOT WATER COST POTENTIAL 112
TOTAL FLOOR AREA 98
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Marsh Close, Cockerham
LOCAL AUTHORITY LABEL Lancaster
CONSTITUENCY LABEL Lancaster and Wyre
POSTTOWN LANCASTER
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2018-08-19 11:55:23
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100010470651
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000002
Address display