Energy Performance Certificate

11, Cherrywood Drive, CO3 4LU

EPC Report

Energy rating

Current: 37 F | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 30 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 80 Potential: 80
Field Value
LMK KEY 8108-9703-4629-7997-1653
ADDRESS1 11, Cherrywood Drive
ADDRESS2
ADDRESS3
POSTCODE CO3 4LU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-06-10
LOCAL AUTHORITY E07000071
CONSTITUENCY E14001176
COUNTY
LODGEMENT DATE 2015-06-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 472
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 8.7
CO2 EMISS CURR PER FLOOR AREA 83
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 105
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 1390
HEATING COST POTENTIAL 555
HOT WATER COST CURRENT 332
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 104
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 92
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 31
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 31% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Cherrywood Drive
LOCAL AUTHORITY LABEL Colchester
CONSTITUENCY LABEL Colchester
POSTTOWN COLCHESTER
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-06-10 18:25:48
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100090444340
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew