58, Longley Road, HA1 4TH

EPC Report

Energy rating

Current: 49 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 43 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 64 Potential: 64
Field Value
LMK KEY 8107-7320-1719-8568-2992
ADDRESS1 58, Longley Road
ADDRESS2
ADDRESS3
POSTCODE HA1 4TH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-10-18
LOCAL AUTHORITY E09000015
CONSTITUENCY E14001271
COUNTY
LODGEMENT DATE 2013-10-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 276
ENERGY CONSUMPTION POTENTIAL 159
CO2 EMISSIONS CURRENT 9.5
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 5.6
LIGHTING COST CURRENT 125
LIGHTING COST POTENTIAL 85
HEATING COST CURRENT 1700
HEATING COST POTENTIAL 1172
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 179
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 86
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 53
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 53% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.81
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 58, Longley Road
LOCAL AUTHORITY LABEL Harrow
CONSTITUENCY LABEL Harrow West
POSTTOWN HARROW
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-10-19 19:22:24
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100021275537
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000007
Address display
Nation ew