Energy Performance Certificate

7, Ragley Close, Poynton, SK12 1DW

EPC Report

Energy rating

Current: 70 C | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 63 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 69 Potential: 69
Field Value
LMK KEY 8107-6556-1629-4807-3113
ADDRESS1 7, Ragley Close
ADDRESS2 Poynton
ADDRESS3
POSTCODE SK12 1DW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-09-05
LOCAL AUTHORITY E06000049
CONSTITUENCY E14001347
COUNTY
LODGEMENT DATE 2019-09-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 188
ENERGY CONSUMPTION POTENTIAL 159
CO2 EMISSIONS CURRENT 8.1
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 6.9
LIGHTING COST CURRENT 124
LIGHTING COST POTENTIAL 124
HEATING COST CURRENT 1373
HEATING COST POTENTIAL 1306
HOT WATER COST CURRENT 138
HOT WATER COST POTENTIAL 138
TOTAL FLOOR AREA 244
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 12
NUMBER HEATED ROOMS 12
LOW ENERGY LIGHTING 97
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 97% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7, Ragley Close, Poynton
LOCAL AUTHORITY LABEL Cheshire East
CONSTITUENCY LABEL Macclesfield
POSTTOWN STOCKPORT
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2019-09-05 18:09:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 39
LOW ENERGY FIXED LIGHT COUNT 38
UPRN 10007953673
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000002
Address display
Nation ew