Energy Performance Certificate

47, South End, Osmotherley, DL6 3BN

EPC Report

Energy rating

Current: 8 G | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 8 G Current: 8 G 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 16 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 66 Potential: 66
Field Value
LMK KEY 8105-6663-4329-9027-2253
ADDRESS1 47, South End
ADDRESS2 Osmotherley
ADDRESS3
POSTCODE DL6 3BN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 8
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-02-26
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001444
COUNTY
LODGEMENT DATE 2015-03-01
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 515
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 19
CO2 EMISS CURR PER FLOOR AREA 113
CO2 EMISSIONS POTENTIAL 5.5
LIGHTING COST CURRENT 153
LIGHTING COST POTENTIAL 83
HEATING COST CURRENT 4004
HEATING COST POTENTIAL 1307
HOT WATER COST CURRENT 266
HOT WATER COST POTENTIAL 111
TOTAL FLOOR AREA 170
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and boiler energy manager
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 11
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and boiler energy manager
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 11% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 47, South End, Osmotherley
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Richmond and Northallerton
POSTTOWN NORTHALLERTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-03-01 16:18:01
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 27
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100050371187
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew