Energy Performance Certificate

52, Sextant Road, HU6 7BA

EPC Report

Energy rating

Current: 62 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 65 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 91 Potential: 91
Field Value
LMK KEY 8104-9608-0229-9676-0643
ADDRESS1 52, Sextant Road
ADDRESS2
ADDRESS3
POSTCODE HU6 7BA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2014-06-30
LOCAL AUTHORITY E06000010
CONSTITUENCY E14001314
COUNTY
LODGEMENT DATE 2014-06-30
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 279
ENERGY CONSUMPTION POTENTIAL 68
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 29
HEATING COST CURRENT 477
HEATING COST POTENTIAL 365
HOT WATER COST CURRENT 84
HOT WATER COST POTENTIAL 50
TOTAL FLOOR AREA 45
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.48
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 52, Sextant Road
LOCAL AUTHORITY LABEL Kingston upon Hull, City of
CONSTITUENCY LABEL Kingston upon Hull North and Cottingham
POSTTOWN HULL
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2014-06-30 12:39:51
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 21083789
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000003
Address display
Nation ew