Energy Performance Certificate

9, Railton Jones Close, Stoke Gifford, BS34 8XY

EPC Report

Energy rating

Current: 92 A | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 92 A Current: 92 A 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 88 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 92 Potential: 92
Field Value
LMK KEY 8104-0645-9622-3726-2603
ADDRESS1 9, Railton Jones Close
ADDRESS2 Stoke Gifford
ADDRESS3
POSTCODE BS34 8XY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 92
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2020-06-24
LOCAL AUTHORITY E06000025
CONSTITUENCY E14001237
COUNTY
LODGEMENT DATE 2020-06-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 44
ENERGY CONSUMPTION POTENTIAL 22
CO2 EMISSIONS CURRENT 0.6
CO2 EMISS CURR PER FLOOR AREA 9
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 434
HEATING COST POTENTIAL 378
HOT WATER COST CURRENT 68
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 400+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 80
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 9, Railton Jones Close, Stoke Gifford
LOCAL AUTHORITY LABEL South Gloucestershire
CONSTITUENCY LABEL Filton and Bradley Stoke
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2020-06-24 13:54:37
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 511142
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000009
Address display
Nation ew