Energy rating

Current: 66 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 63 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 80 Potential: 80
Field Value
LMK KEY 8103-7830-0129-1497-0123
ADDRESS1 3 Kings Gate
ADDRESS2 School Lane
ADDRESS3 Sandiway
POSTCODE CW8 2NH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-09-17
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001164
COUNTY
LODGEMENT DATE 2012-09-19
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 201
ENERGY CONSUMPTION POTENTIAL 107
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 39
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 99
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 836
HEATING COST POTENTIAL 669
HOT WATER COST CURRENT 88
HOT WATER COST POTENTIAL 88
TOTAL FLOOR AREA 130
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 46
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 46% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3 Kings Gate, School Lane, Sandiway
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Chester South and Eddisbury
POSTTOWN NORTHWICH
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2012-09-19 17:54:03
TENURE
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100012604469
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000002
Address display