Energy Performance Certificate

6, Brellows Hill, Terrington St. Clement, PE34 4PF

EPC Report

Energy rating

Current: 67 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 59 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 76 Potential: 76
Field Value
LMK KEY 8103-1702-5029-8797-0743
ADDRESS1 6, Brellows Hill
ADDRESS2 Terrington St. Clement
ADDRESS3
POSTCODE PE34 4PF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-03-10
LOCAL AUTHORITY E07000146
CONSTITUENCY E14001405
COUNTY
LODGEMENT DATE 2014-03-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 195
ENERGY CONSUMPTION POTENTIAL 97
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 97
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 613
HEATING COST POTENTIAL 554
HOT WATER COST CURRENT 167
HOT WATER COST POTENTIAL 113
TOTAL FLOOR AREA 84
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Brellows Hill, Terrington St. Clement
LOCAL AUTHORITY LABEL King's Lynn and West Norfolk
CONSTITUENCY LABEL North West Norfolk
POSTTOWN KING'S LYNN
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2014-03-10 16:07:49
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100090968276
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew