Energy Performance Certificate

25, Meadway, RM17 5TA

EPC Report

Energy rating

Current: 1 G | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 16 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 79 Potential: 79
Field Value
LMK KEY 8102-4479-3729-0096-3423
ADDRESS1 25, Meadway
ADDRESS2
ADDRESS3
POSTCODE RM17 5TA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2012-04-13
LOCAL AUTHORITY E06000034
CONSTITUENCY E14001546
COUNTY
LODGEMENT DATE 2012-04-14
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 702
ENERGY CONSUMPTION POTENTIAL 110
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 128
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 70
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 2528
HEATING COST POTENTIAL 495
HOT WATER COST CURRENT 238
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 86
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.48
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 25, Meadway
LOCAL AUTHORITY LABEL Thurrock
CONSTITUENCY LABEL Thurrock
POSTTOWN GRAYS
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2012-04-14 10:25:19
TENURE
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100090730926
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000006
Address display