Energy Performance Certificate

33, Bowden Hill, Lacock, SN15 2PP

EPC Report

Energy rating

Current: 73 C | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 78 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 88 Potential: 88
Field Value
LMK KEY 8101-6125-7840-9475-4996
ADDRESS1 33, Bowden Hill
ADDRESS2 Lacock
ADDRESS3
POSTCODE SN15 2PP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-05-15
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001168
COUNTY
LODGEMENT DATE 2019-05-16
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 114
ENERGY CONSUMPTION POTENTIAL 58
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 131
LIGHTING COST POTENTIAL 131
HEATING COST CURRENT 1597
HEATING COST POTENTIAL 1597
HOT WATER COST CURRENT 133
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 300
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity and internal insulation
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 400+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.47
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 33, Bowden Hill, Lacock
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL Chippenham
POSTTOWN CHIPPENHAM
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2019-05-16 18:13:45
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 30
UPRN 10070784136
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew