Energy Performance Certificate

1, Biddlecombe Orchard, DT6 5RS

EPC Report

Energy rating

Current: 53 E | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 31 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 Current: 31 72 Potential: 72
Field Value
LMK KEY 8100-7254-1929-5196-2543
ADDRESS1 1, Biddlecombe Orchard
ADDRESS2
ADDRESS3
POSTCODE DT6 5RS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-05-15
LOCAL AUTHORITY E06000059
CONSTITUENCY E14001575
COUNTY
LODGEMENT DATE 2014-05-17
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 31
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 543
ENERGY CONSUMPTION POTENTIAL 171
CO2 EMISSIONS CURRENT 5.7
CO2 EMISS CURR PER FLOOR AREA 96
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 684
HEATING COST POTENTIAL 319
HOT WATER COST CURRENT 121
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 60
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Biddlecombe Orchard
LOCAL AUTHORITY LABEL Dorset
CONSTITUENCY LABEL West Dorset
POSTTOWN BRIDPORT
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2014-05-17 20:05:53
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 200000751384
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000009
Address display