Energy Performance Certificate

200, Winsover Road, PE11 1HQ

EPC Report

Energy rating

Current: 42 E | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 36 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 86 Potential: 86
Field Value
LMK KEY 8100-7253-9129-6607-0953
ADDRESS1 200, Winsover Road
ADDRESS2
ADDRESS3
POSTCODE PE11 1HQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-01-05
LOCAL AUTHORITY E07000140
CONSTITUENCY E14001487
COUNTY
LODGEMENT DATE 2015-01-05
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 492
ENERGY CONSUMPTION POTENTIAL 82
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 87
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 44
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 974
HEATING COST POTENTIAL 399
HOT WATER COST CURRENT 227
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 68
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.58
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 200, Winsover Road
LOCAL AUTHORITY LABEL South Holland
CONSTITUENCY LABEL South Holland and The Deepings
POSTTOWN SPALDING
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-01-05 12:36:37
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100030899305
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew