Energy Performance Certificate

183, Elwick Road, TS26 9NP

EPC Report

Energy rating

Current: 61 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 53 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 78 Potential: 78
Field Value
LMK KEY 8100-6252-4029-8327-4643
ADDRESS1 183, Elwick Road
ADDRESS2
ADDRESS3
POSTCODE TS26 9NP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2014-06-25
LOCAL AUTHORITY E06000001
CONSTITUENCY E14001272
COUNTY
LODGEMENT DATE 2014-06-25
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 216
ENERGY CONSUMPTION POTENTIAL 103
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 5.6
LIGHTING COST CURRENT 152
LIGHTING COST POTENTIAL 103
HEATING COST CURRENT 2154
HEATING COST POTENTIAL 1186
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 106
TOTAL FLOOR AREA 277
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 53
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 53% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 183, Elwick Road
LOCAL AUTHORITY LABEL Hartlepool
CONSTITUENCY LABEL Hartlepool
POSTTOWN HARTLEPOOL
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-06-25 14:20:03
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100110010525
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000001
Address display
Nation ew