Energy Performance Certificate

1, Harold Road, Worth, RH10 7RD

EPC Report

Energy rating

Current: 69 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 65 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 79 Potential: 79
Field Value
LMK KEY 8100-3720-0729-1507-2573
ADDRESS1 1, Harold Road
ADDRESS2 Worth
ADDRESS3
POSTCODE RH10 7RD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-05-02
LOCAL AUTHORITY E07000226
CONSTITUENCY E14001184
COUNTY
LODGEMENT DATE 2013-05-02
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 161
ENERGY CONSUMPTION POTENTIAL 87
CO2 EMISSIONS CURRENT 5.3
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 115
LIGHTING COST POTENTIAL 83
HEATING COST CURRENT 844
HEATING COST POTENTIAL 688
HOT WATER COST CURRENT 149
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 173
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Harold Road, Worth
LOCAL AUTHORITY LABEL Crawley
CONSTITUENCY LABEL Crawley
POSTTOWN CRAWLEY
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2013-05-02 12:49:37
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 100061778262
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000008
Address display
Nation ew