Energy Performance Certificate

1, Mount Pleasant, Stockton, CV47 8JW

EPC Report

Energy rating

Current: 11 G | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 G Current: 11 G 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 1 | Potential: 33
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 33 Potential: 33
Field Value
LMK KEY 8097-7229-1839-2632-8996
ADDRESS1 1, Mount Pleasant
ADDRESS2 Stockton
ADDRESS3
POSTCODE CV47 8JW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 11
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-11-12
LOCAL AUTHORITY E07000221
CONSTITUENCY E14001309
COUNTY
LODGEMENT DATE 2013-11-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 33
ENERGY CONSUMPTION CURRENT 1141
ENERGY CONSUMPTION POTENTIAL 435
CO2 EMISSIONS CURRENT 21
CO2 EMISS CURR PER FLOOR AREA 222
CO2 EMISSIONS POTENTIAL 7.7
LIGHTING COST CURRENT 115
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 2203
HEATING COST POTENTIAL 906
HOT WATER COST CURRENT 289
HOT WATER COST POTENTIAL 90
TOTAL FLOOR AREA 94
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Mount Pleasant, Stockton
LOCAL AUTHORITY LABEL Stratford-on-Avon
CONSTITUENCY LABEL Kenilworth and Southam
POSTTOWN SOUTHAM
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-11-12 14:30:21
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100070209342
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew