Energy Performance Certificate

The Arches Beynon Court, Porteynon, SA3 1NL

EPC Report

Energy rating

Current: 76 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 79 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 90 Potential: 90
Field Value
LMK KEY 8095-1674-9739-8107-4063
ADDRESS1 The Arches Beynon Court
ADDRESS2 Porteynon
ADDRESS3
POSTCODE SA3 1NL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-10-03
LOCAL AUTHORITY W06000011
CONSTITUENCY W07000097
COUNTY
LODGEMENT DATE 2016-10-03
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 127
ENERGY CONSUMPTION POTENTIAL 48
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 21
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 284
HEATING COST POTENTIAL 284
HOT WATER COST CURRENT 376
HOT WATER COST POTENTIAL 232
TOTAL FLOOR AREA 114
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.18 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.15 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS The Arches Beynon Court, Porteynon
LOCAL AUTHORITY LABEL Swansea
CONSTITUENCY LABEL Gower
POSTTOWN SWANSEA
CONSTRUCTION AGE BAND 2015
LODGEMENT DATETIME 2016-10-03 16:54:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 22
UPRN 10091614894
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew