Energy Performance Certificate

Argyll House, Townsend, Urchfont, SN10 4RR

EPC Report

Energy rating

Current: 56 D | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 47 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 63 Potential: 63
Field Value
LMK KEY 8090-8049-0622-5107-3093
ADDRESS1 Argyll House
ADDRESS2 Townsend
ADDRESS3 Urchfont
POSTCODE SN10 4RR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-10-04
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001356
COUNTY
LODGEMENT DATE 2021-10-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 209
ENERGY CONSUMPTION POTENTIAL 124
CO2 EMISSIONS CURRENT 7.2
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 4.7
LIGHTING COST CURRENT 126
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 878
HEATING COST POTENTIAL 707
HOT WATER COST CURRENT 186
HOT WATER COST POTENTIAL 150
TOTAL FLOOR AREA 137
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Argyll House, Townsend, Urchfont
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL Melksham and Devizes
POSTTOWN DEVIZES
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2021-10-05 12:27:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 200001181850
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000009
Address display
Nation ew