Energy Performance Certificate

31, Withywood Drive, TF3 2HT

EPC Report

Energy rating

Current: 75 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 75 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 82 Potential: 82
Field Value
LMK KEY 8090-7428-7890-8169-7296
ADDRESS1 31, Withywood Drive
ADDRESS2
ADDRESS3
POSTCODE TF3 2HT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2020-08-11
LOCAL AUTHORITY E06000020
CONSTITUENCY E14001541
COUNTY
LODGEMENT DATE 2020-08-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 175
ENERGY CONSUMPTION POTENTIAL 127
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 108
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 377
HEATING COST POTENTIAL 284
HOT WATER COST CURRENT 92
HOT WATER COST POTENTIAL 92
TOTAL FLOOR AREA 74
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31, Withywood Drive
LOCAL AUTHORITY LABEL Telford and Wrekin
CONSTITUENCY LABEL Telford
POSTTOWN TELFORD
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2020-08-11 22:59:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 452020536
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000005
Address display