Energy Performance Certificate

18, Sandeman Crescent, CW8 4ZG

EPC Report

Energy rating

Current: 79 C | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 79 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 91 Potential: 91
Field Value
LMK KEY 8086-7233-4530-9683-7922
ADDRESS1 18, Sandeman Crescent
ADDRESS2
ADDRESS3
POSTCODE CW8 4ZG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-07-27
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001361
COUNTY
LODGEMENT DATE 2016-07-27
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 116
ENERGY CONSUMPTION POTENTIAL 46
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 116
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 328
HEATING COST POTENTIAL 338
HOT WATER COST CURRENT 125
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 107
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 38
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.19 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.31 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.18 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 38% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 18, Sandeman Crescent
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Mid Cheshire
POSTTOWN NORTHWICH
CONSTRUCTION AGE BAND 2007
LODGEMENT DATETIME 2016-07-27 16:00:24
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10091138912
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew