Energy Performance Certificate

4, Maes Emlyn, LL18 3SF

EPC Report

Energy rating

Current: 60 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 47 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 63 Potential: 63
Field Value
LMK KEY 8068-6429-5190-6575-5926
ADDRESS1 4, Maes Emlyn
ADDRESS2
ADDRESS3
POSTCODE LL18 3SF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2018-01-25
LOCAL AUTHORITY W06000004
CONSTITUENCY W07000095
COUNTY
LODGEMENT DATE 2018-01-26
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 430
ENERGY CONSUMPTION POTENTIAL 297
CO2 EMISSIONS CURRENT 3.5
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 411
HEATING COST POTENTIAL 222
HOT WATER COST CURRENT 249
HOT WATER COST POTENTIAL 131
TOTAL FLOOR AREA 48
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 8.43
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, Maes Emlyn
LOCAL AUTHORITY LABEL Denbighshire
CONSTITUENCY LABEL Clwyd North
POSTTOWN RHYL
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2018-01-26 20:52:22
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100100200687
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew