Energy Performance Certificate

2a, Sprimont Place, SW3 3HU

EPC Report

Energy rating

Current: 44 E | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 34 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 63 Potential: 63
Field Value
LMK KEY 8065-7129-2799-8526-0996
ADDRESS1 2a, Sprimont Place
ADDRESS2
ADDRESS3
POSTCODE SW3 3HU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-11-16
LOCAL AUTHORITY E09000020
CONSTITUENCY E14001160
COUNTY
LODGEMENT DATE 2015-11-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 310
ENERGY CONSUMPTION POTENTIAL 136
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 55
CO2 EMISSIONS POTENTIAL 5.3
LIGHTING COST CURRENT 133
LIGHTING COST POTENTIAL 97
HEATING COST CURRENT 2092
HEATING COST POTENTIAL 1182
HOT WATER COST CURRENT 285
HOT WATER COST POTENTIAL 91
TOTAL FLOOR AREA 219
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Full secondary glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.68
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2a, Sprimont Place
LOCAL AUTHORITY LABEL Kensington and Chelsea
CONSTITUENCY LABEL Chelsea and Fulham
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-11-18 15:40:27
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 40
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 217077399
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew