Energy Performance Certificate

211, Berkeley Road, B25 8NJ

EPC Report

Energy rating

Current: 62 D | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 60 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 62 Potential: 62
Field Value
LMK KEY 8065-6925-5590-0475-1902
ADDRESS1 211, Berkeley Road
ADDRESS2
ADDRESS3
POSTCODE B25 8NJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2015-05-05
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001100
COUNTY
LODGEMENT DATE 2015-05-22
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 333
ENERGY CONSUMPTION POTENTIAL 310
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 64
LIGHTING COST POTENTIAL 32
HEATING COST CURRENT 513
HEATING COST POTENTIAL 500
HOT WATER COST CURRENT 80
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 46
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 7.28
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 211, Berkeley Road
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Yardley
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-05-22 10:07:40
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100070292565
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000005
Address display
Nation ew