Energy Performance Certificate

1, Cherry Tree Avenue, Barnton, CW8 4LX

EPC Report

Energy rating

Current: 17 G | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 G Current: 17 G 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 27 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 80 Potential: 80
Field Value
LMK KEY 8056-7222-4400-4245-5906
ADDRESS1 1, Cherry Tree Avenue
ADDRESS2 Barnton
ADDRESS3
POSTCODE CW8 4LX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 17
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-02-05
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001539
COUNTY
LODGEMENT DATE 2016-02-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 544
ENERGY CONSUMPTION POTENTIAL 112
CO2 EMISSIONS CURRENT 8.1
CO2 EMISS CURR PER FLOOR AREA 93
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 1830
HEATING COST POTENTIAL 517
HOT WATER COST CURRENT 334
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 87
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Cherry Tree Avenue, Barnton
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Tatton
POSTTOWN NORTHWICH
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2016-02-05 19:14:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100010181528
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew