Energy Performance Certificate

55, Station Road, Haddenham, CB6 3XD

EPC Report

Energy rating

Current: 29 F | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 F Current: 29 F 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 26 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 66 Potential: 66
Field Value
LMK KEY 8051-7825-6480-6477-4922
ADDRESS1 55, Station Road
ADDRESS2 Haddenham
ADDRESS3
POSTCODE CB6 3XD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 29
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-05-23
LOCAL AUTHORITY E07000009
CONSTITUENCY E14001224
COUNTY
LODGEMENT DATE 2019-06-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 399
ENERGY CONSUMPTION POTENTIAL 120
CO2 EMISSIONS CURRENT 7.8
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 64
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 933
HEATING COST POTENTIAL 372
HOT WATER COST CURRENT 123
HOT WATER COST POTENTIAL 136
TOTAL FLOOR AREA 74
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 83
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 55, Station Road, Haddenham
LOCAL AUTHORITY LABEL East Cambridgeshire
CONSTITUENCY LABEL Ely and East Cambridgeshire
POSTTOWN ELY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-06-04 07:59:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100090054389
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew