Energy Performance Certificate

1, Ty Bad, SA44 4QT

EPC Report

Energy rating

Current: 32 F | Potential: 106 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 106 A Potential: 106 A

Environmental impact (CO₂)

Current: 75 | Potential: 121
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 121 Potential: 121
Field Value
LMK KEY 8043-7126-3310-0600-5972
ADDRESS1 1, Ty Bad
ADDRESS2
ADDRESS3
POSTCODE SA44 4QT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 106
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2017-06-30
LOCAL AUTHORITY W06000008
CONSTITUENCY W07000093
COUNTY
LODGEMENT DATE 2017-07-02
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 121
ENERGY CONSUMPTION CURRENT 513
ENERGY CONSUMPTION POTENTIAL -1
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL -1.8
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 1488
HEATING COST POTENTIAL 633
HOT WATER COST CURRENT 141
HOT WATER COST POTENTIAL 61
TOTAL FLOOR AREA 74
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Room heaters, wood logs
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL wood logs
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Ty Bad
LOCAL AUTHORITY LABEL Ceredigion
CONSTITUENCY LABEL Ceredigion Preseli
POSTTOWN LLANDYSUL
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-07-02 10:09:32
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 49034506
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew