Energy Performance Certificate

Staddles, Windmill Hill, Ashill, TA19 9NT

EPC Report

Energy rating

Current: 29 F | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 F Current: 29 F 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 25 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 72 Potential: 72
Field Value
LMK KEY 8020-7421-2050-4779-0296
ADDRESS1 Staddles
ADDRESS2 Windmill Hill
ADDRESS3 Ashill
POSTCODE TA19 9NT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 29
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-09-11
LOCAL AUTHORITY E06000066
CONSTITUENCY E14001603
COUNTY
LODGEMENT DATE 2020-09-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 289
ENERGY CONSUMPTION POTENTIAL 74
CO2 EMISSIONS CURRENT 17
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 4.8
LIGHTING COST CURRENT 175
LIGHTING COST POTENTIAL 125
HEATING COST CURRENT 2537
HEATING COST POTENTIAL 824
HOT WATER COST CURRENT 223
HOT WATER COST POTENTIAL 88
TOTAL FLOOR AREA 233
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Full secondary glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.91
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Staddles, Windmill Hill, Ashill
LOCAL AUTHORITY LABEL Somerset
CONSTITUENCY LABEL Yeovil
POSTTOWN ILMINSTER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-09-14 10:57:15
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 30100890
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000009
Address display
Nation ew