Energy Performance Certificate

2, Granville Road, LS9 7LW

EPC Report

Energy rating

Current: 42 E | Potential: 47 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 47 E Potential: 47 E

Environmental impact (CO₂)

Current: 22 | Potential: 26
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 26 Potential: 26
Field Value
LMK KEY 8013-7526-5920-6243-9926
ADDRESS1 2, Granville Road
ADDRESS2
ADDRESS3
POSTCODE LS9 7LW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 47
PROPERTY TYPE Maisonette
BUILT FORM End-Terrace
INSPECTION DATE 2017-06-27
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001323
COUNTY
LODGEMENT DATE 2017-06-27
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 26
ENERGY CONSUMPTION CURRENT 683
ENERGY CONSUMPTION POTENTIAL 626
CO2 EMISSIONS CURRENT 8.9
CO2 EMISS CURR PER FLOOR AREA 115
CO2 EMISSIONS POTENTIAL 8.1
LIGHTING COST CURRENT 109
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 1190
HEATING COST POTENTIAL 1097
HOT WATER COST CURRENT 167
HOT WATER COST POTENTIAL 167
TOTAL FLOOR AREA 77
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 22
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric underfloor heating
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 22% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Granville Road
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds South
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2017-06-27 16:03:01
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 72081252
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000003
Address display
Nation ew