Energy Performance Certificate

The Annexe, 3 Ashley Road, Weston by Welland, LE16 8HR

EPC Report

Energy rating

Current: 72 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 47 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 64 Potential: 64
Field Value
LMK KEY 8011-7331-6190-0641-7996
ADDRESS1 The Annexe
ADDRESS2 3 Ashley Road
ADDRESS3 Weston by Welland
POSTCODE LE16 8HR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2019-09-19
LOCAL AUTHORITY E06000061
CONSTITUENCY E14001311
COUNTY
LODGEMENT DATE 2019-09-19
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 458
ENERGY CONSUMPTION POTENTIAL 293
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 47
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 445
HEATING COST POTENTIAL 449
HOT WATER COST CURRENT 143
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 49
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Average thermal transmittance 0.22 W/m²K
FLOOR ENERGY EFF Good
FLOOR ENV EFF Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.34 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.17 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS The Annexe, 3 Ashley Road, Weston by Welland
LOCAL AUTHORITY LABEL North Northamptonshire
CONSTITUENCY LABEL Kettering
POSTTOWN MARKET HARBOROUGH
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2019-09-19 16:09:45
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100031080909
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2019.csv
COUNTRY England
REGION E12000004
Address display
Nation ew