Energy Performance Certificate

30 Albion Drive, E8 4ET

EPC Report

Energy rating

Current: 26 F | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 F Current: 26 F 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 36 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 63 Potential: 63
Field Value
LMK KEY 8011-1124-2002-0091-2706
ADDRESS1 30 Albion Drive
ADDRESS2
ADDRESS3
POSTCODE E8 4ET
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 26
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-09-10
LOCAL AUTHORITY E09000012
CONSTITUENCY E14001260
COUNTY
LODGEMENT DATE 2024-09-16
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 370
ENERGY CONSUMPTION POTENTIAL 175
CO2 EMISSIONS CURRENT 6.9
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 316
LIGHTING COST POTENTIAL 199
HEATING COST CURRENT 3227
HEATING COST POTENTIAL 1012
HOT WATER COST CURRENT 1306
HOT WATER COST POTENTIAL 216
TOTAL FLOOR AREA 110
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 48
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 30 Albion Drive
LOCAL AUTHORITY LABEL Hackney
CONSTITUENCY LABEL Hackney South and Shoreditch
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-09-16 13:48:38
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 1
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100021021871
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew