Energy Performance Certificate

101, Connaught Road, Brookwood, GU24 0EU

EPC Report

Energy rating

Current: 23 F | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 F Current: 23 F 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 32 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 87 Potential: 87
Field Value
LMK KEY 8009-3935-2829-8627-6683
ADDRESS1 101, Connaught Road
ADDRESS2 Brookwood
ADDRESS3
POSTCODE GU24 0EU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 23
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2018-06-27
LOCAL AUTHORITY E07000217
CONSTITUENCY E14001592
COUNTY
LODGEMENT DATE 2018-06-27
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 522
ENERGY CONSUMPTION POTENTIAL 66
CO2 EMISSIONS CURRENT 6.3
CO2 EMISS CURR PER FLOOR AREA 90
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 1487
HEATING COST POTENTIAL 335
HOT WATER COST CURRENT 248
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 70
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From secondary system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 101, Connaught Road, Brookwood
LOCAL AUTHORITY LABEL Woking
CONSTITUENCY LABEL Woking
POSTTOWN WOKING
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2018-06-27 23:25:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100061641954
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew