Energy Performance Certificate

27, The Prebend, Northend, CV47 2TR

EPC Report

Energy rating

Current: 54 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 26 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 50 Potential: 50
Field Value
LMK KEY 8008-6023-6980-1619-1992
ADDRESS1 27, The Prebend
ADDRESS2 Northend
ADDRESS3
POSTCODE CV47 2TR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2018-07-11
LOCAL AUTHORITY E07000221
CONSTITUENCY E14001309
COUNTY
LODGEMENT DATE 2018-09-28
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 531
ENERGY CONSUMPTION POTENTIAL 296
CO2 EMISSIONS CURRENT 8.2
CO2 EMISS CURR PER FLOOR AREA 105
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 88
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 885
HEATING COST POTENTIAL 614
HOT WATER COST CURRENT 171
HOT WATER COST POTENTIAL 98
TOTAL FLOOR AREA 78
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 55
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 55% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 27, The Prebend, Northend
LOCAL AUTHORITY LABEL Stratford-on-Avon
CONSTITUENCY LABEL Kenilworth and Southam
POSTTOWN SOUTHAM
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2018-09-28 14:14:00
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100070210661
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000005
Address display
Nation ew