Energy Performance Certificate

Mablethorpe Chalet Park Ltd, Links Avenue, LN12 1QN

EPC Report

Energy rating

Current: 17 G | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 G Current: 17 G 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 29 | Potential: 43
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 43 Potential: 43
Field Value
LMK KEY 8006-3992-3729-1597-8763
ADDRESS1 Mablethorpe Chalet Park Ltd
ADDRESS2 Links Avenue
ADDRESS3
POSTCODE LN12 1QN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 17
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE Park home
BUILT FORM Detached
INSPECTION DATE 2016-03-11
LOCAL AUTHORITY E07000137
CONSTITUENCY E14001343
COUNTY
LODGEMENT DATE 2016-03-11
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 43
ENERGY CONSUMPTION CURRENT 987
ENERGY CONSUMPTION POTENTIAL 688
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 167
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 24
HEATING COST CURRENT 1138
HEATING COST POTENTIAL 407
HOT WATER COST CURRENT 131
HOT WATER COST POTENTIAL 145
TOTAL FLOOR AREA 27
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Park home wall, as built
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Mablethorpe Chalet Park Ltd, Links Avenue
LOCAL AUTHORITY LABEL East Lindsey
CONSTITUENCY LABEL Louth and Horncastle
POSTTOWN MABLETHORPE
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2016-03-11 14:13:36
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100032079907
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew