Energy Performance Certificate

304, Cassiobury Drive, WD17 3AP

EPC Report

Energy rating

Current: 43 E | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 39 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 66 Potential: 66
Field Value
LMK KEY 8006-0202-6329-8577-6543
ADDRESS1 304, Cassiobury Drive
ADDRESS2
ADDRESS3
POSTCODE WD17 3AP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 43
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-05-30
LOCAL AUTHORITY E07000103
CONSTITUENCY E14001568
COUNTY
LODGEMENT DATE 2014-05-30
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 344
ENERGY CONSUMPTION POTENTIAL 168
CO2 EMISSIONS CURRENT 7.3
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 1252
HEATING COST POTENTIAL 888
HOT WATER COST CURRENT 231
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 110
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 304, Cassiobury Drive
LOCAL AUTHORITY LABEL Watford
CONSTITUENCY LABEL Watford
POSTTOWN WATFORD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-05-30 12:00:00
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100080931067
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew