Energy Performance Certificate

35, King Georges Close, SS6 8JL

EPC Report

Energy rating

Current: 65 D | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 45 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 75 Potential: 75
Field Value
LMK KEY 8005-7929-3299-4958-9902
ADDRESS1 35, King Georges Close
ADDRESS2
ADDRESS3
POSTCODE SS6 8JL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Enclosed Mid-Terrace
INSPECTION DATE 2015-11-08
LOCAL AUTHORITY E07000075
CONSTITUENCY E14001437
COUNTY
LODGEMENT DATE 2015-11-08
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 375
ENERGY CONSUMPTION POTENTIAL 142
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 516
HEATING COST POTENTIAL 316
HOT WATER COST CURRENT 168
HOT WATER COST POTENTIAL 88
TOTAL FLOOR AREA 73
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Less Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35, King Georges Close
LOCAL AUTHORITY LABEL Rochford
CONSTITUENCY LABEL Rayleigh and Wickford
POSTTOWN RAYLEIGH
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2015-11-08 15:16:08
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100090581891
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew