Energy Performance Certificate

Flat 5, 85-87, Stricklandgate, LA9 4RA

EPC Report

Energy rating

Current: 52 E | Potential: 53 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 53 E Potential: 53 E

Environmental impact (CO₂)

Current: 57 | Potential: 57
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 57 Potential: 57
Field Value
LMK KEY 8005-7407-7122-8696-8703
ADDRESS1 Flat 5
ADDRESS2 85-87, Stricklandgate
ADDRESS3
POSTCODE LA9 4RA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 53
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2020-03-10
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001580
COUNTY
LODGEMENT DATE 2020-03-13
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 57
ENERGY CONSUMPTION CURRENT 308
ENERGY CONSUMPTION POTENTIAL 301
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 4.0
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 970
HEATING COST POTENTIAL 939
HOT WATER COST CURRENT 353
HOT WATER COST POTENTIAL 353
TOTAL FLOOR AREA 79
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric underfloor heating
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.806
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 5, 85-87, Stricklandgate
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Westmorland and Lonsdale
POSTTOWN KENDAL
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2020-03-13 14:24:02
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10002461419
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display