Energy Performance Certificate

Holly Cottage, Graig Penllyn, CF71 7RT

EPC Report

Energy rating

Current: 32 F | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 27 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 55 Potential: 55
Field Value
LMK KEY 8005-6964-4629-9227-8863
ADDRESS1 Holly Cottage
ADDRESS2 Graig Penllyn
ADDRESS3
POSTCODE CF71 7RT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-08-26
LOCAL AUTHORITY W06000014
CONSTITUENCY W07000110
COUNTY
LODGEMENT DATE 2016-09-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 299
ENERGY CONSUMPTION POTENTIAL 140
CO2 EMISSIONS CURRENT 14
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 6.8
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 102
HEATING COST CURRENT 1870
HEATING COST POTENTIAL 1135
HOT WATER COST CURRENT 272
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 178
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 60
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 85
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 85% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Holly Cottage, Graig Penllyn
LOCAL AUTHORITY LABEL Vale of Glamorgan
CONSTITUENCY LABEL Vale of Glamorgan
POSTTOWN COWBRIDGE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-09-01 17:42:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 64029082
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew