Energy Performance Certificate

17, The Old Common, Chalford, GL6 8HH

EPC Report

Energy rating

Current: 64 D | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 62 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 89 Potential: 89
Field Value
LMK KEY 8005-3044-2729-6806-8263
ADDRESS1 17, The Old Common
ADDRESS2 Chalford
ADDRESS3
POSTCODE GL6 8HH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-02-04
LOCAL AUTHORITY E07000082
CONSTITUENCY E14001529
COUNTY
LODGEMENT DATE 2016-02-04
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 301
ENERGY CONSUMPTION POTENTIAL 74
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 36
HEATING COST CURRENT 497
HEATING COST POTENTIAL 357
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 56
TOTAL FLOOR AREA 51
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.26
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 17, The Old Common, Chalford
LOCAL AUTHORITY LABEL Stroud
CONSTITUENCY LABEL Stroud
POSTTOWN STROUD
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2016-02-04 12:31:53
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100120521181
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000009
Address display
Nation ew